| // Copyright 2021 The Fuchsia Authors | |
| // | |
| // Use of this source code is governed by a MIT-style | |
| // license that can be found in the LICENSE file or at | |
| // https://opensource.org/licenses/MIT | |
| //! Inline implementations of the lockup detector critical section entry and exit paths. | |
| use core::ffi::{CStr, c_char}; | |
| use core::ptr::{self, NonNull}; | |
| use core::sync::atomic::{Ordering, compiler_fence}; | |
| use super::LOCKUP_CRITICAL_SECTION_ENABLED; | |
| use super::state::LockupDetectorState; | |
| use crate::arch_rs::curr_cpu_num; | |
| use crate::kernel::types::cpu_num_t; | |
| /// Enter a critical section. | |
| /// | |
| /// Returns true if this is the outermost critical section. | |
| /// | |
| /// Don't forget to call [`call_if_outer_and_leave`] (regardless of this function's return value). | |
| #[inline] | |
| pub(super) fn enter(state: &LockupDetectorState) -> bool { | |
| let cs_state = &state.critical_section; | |
| // We must maintain the invariant that if a call to `enter` increments the depth, the matching | |
| // call to `call_if_outer_and_leave` decrements it. The most reliable way to accomplish that | |
| // is to always increment and always decrement. | |
| // | |
| // `depth` is only ever accessed by this CPU, so relaxed loads and stores are all the | |
| // atomicity it needs; the compiler fences below order it against the rest of the state. | |
| let depth = cs_state.depth.load(Ordering::Relaxed) + 1; | |
| cs_state.depth.store(depth, Ordering::Relaxed); | |
| if depth != 1 { | |
| core::hint::cold_path(); | |
| return false; | |
| } | |
| // This is the outermost critical section. However, we may be racing with an interrupt handler | |
| // that may call into `enter`. Use a compiler fence to ensure that the compiler cannot | |
| // reorder upcoming stores to precede the depth=1 store above. If the compiler were to make | |
| // such a reordering the `enter` call made by the interrupt handler may incorrectly believe | |
| // its critical section is the outermost critical section because it has not seen our depth=1 | |
| // store. | |
| // | |
| // Note, there is a small gap here where the CriticalSectionLockupChecker may fail to notice a | |
| // lockup (though the HeartbeatLockupChecker may still detect it). Consider the following: | |
| // | |
| // 1. We have stored depth=1, but not yet stored begin_ticks. | |
| // 2. An interrupt fires and the handler calls `enter`. | |
| // 3. The handler sees that depth is 1 so it does nothing. | |
| // 4. The CPU enters an infinite loop. | |
| // 5. CriticalSectionLockupChecker sees that begin_ticks has not been set so it assumes the | |
| // CPU is not in a section. | |
| // | |
| // If interrupts are enabled at the time of the infinite loop in step 4, the system may never | |
| // detect the problem. If instead of an infinite loop we just spend a lot of time in the | |
| // interrupt handler, we may never know it because the begin_ticks would only get set by the | |
| // outer critical section *after* returning from the handler. | |
| // | |
| // One way to close the gap would be to use begin_ticks rather than depth to determine if we're | |
| // already in a critical section. Instead of storing begin_ticks when depth=1, we would store | |
| // begin_ticks only if it's currently unset (i.e. use an atomic compare and exchange with an | |
| // expected value of 0). However, this would increase the cost of critical section | |
| // instrumentation. Because the gap is small and we have heartbeats we have chosen to live | |
| // with it rather than pay the price of atomic compare and exchange. | |
| compiler_fence(Ordering::SeqCst); | |
| true | |
| } | |
| /// Call `func` if in the outermost critical section then leave the current critical section. | |
| #[inline] | |
| pub(super) fn call_if_outer_and_leave<F: FnOnce(&LockupDetectorState)>( | |
| state: &LockupDetectorState, | |
| func: F, | |
| ) { | |
| let cs_state = &state.critical_section; | |
| // See `enter` for why relaxed loads and stores of `depth` suffice. | |
| let depth = cs_state.depth.load(Ordering::Relaxed); | |
| if depth == 1 { | |
| // This is the outermost critical section. However, we may be racing with an interrupt | |
| // handler that may call into `enter`. Use compiler fences before and after `func` so | |
| // `func`'s stores cannot be compiler-reordered ahead of the `depth` load above, and the | |
| // `depth - 1` store below cannot be compiler-reordered ahead of `func` clearing critical | |
| // section state. | |
| compiler_fence(Ordering::SeqCst); | |
| func(state); | |
| compiler_fence(Ordering::SeqCst); | |
| } else { | |
| core::hint::cold_path(); | |
| } | |
| debug_assert!(depth > 0); | |
| cs_state.depth.store(depth - 1, Ordering::Relaxed); | |
| } | |
| /// Used to indicate the CPU is entering a critical section with name `name` where it might appear | |
| /// to be locked up. | |
| /// | |
| /// # Safety | |
| /// | |
| /// - Preemption or interrupts must be disabled on the calling CPU and remain disabled until the | |
| /// matching [`lockup_end`] call on the same CPU. | |
| /// - Any interrupt handler on the same CPU that enters a critical section while preemption is | |
| /// disabled must balance its own `begin`/`end` calls before returning. | |
| #[inline] | |
| pub unsafe fn lockup_begin(name: &'static CStr) { | |
| // SAFETY: `curr_cpu_num()` is the calling CPU's valid index below `SMP_MAX_CPUS`, `name` is a | |
| // NUL-terminated C string with static lifetime, and the caller upholds the remaining | |
| // preconditions. | |
| unsafe { lockup_begin_raw_on_cpu(curr_cpu_num(), NonNull::from(name).cast()) }; | |
| } | |
| /// [`lockup_begin`] when the caller has already loaded `curr_cpu_num()` into `cpu` and only has a | |
| /// thin pointer to `name`. | |
| /// | |
| /// # Safety | |
| /// | |
| /// - `cpu` must equal `curr_cpu_num()` (`< SMP_MAX_CPUS`). | |
| /// - `name` must point to a NUL-terminated C string with static lifetime. | |
| /// - Preemption or interrupts must be disabled on the calling CPU and remain disabled until the | |
| /// matching [`lockup_end`] call on the same CPU. | |
| /// - Any interrupt handler on the same CPU that enters a critical section while preemption is | |
| /// disabled must balance its own `begin`/`end` calls before returning. | |
| #[inline] | |
| pub unsafe fn lockup_begin_raw_on_cpu(cpu: cpu_num_t, name: NonNull<c_char>) { | |
| if !LOCKUP_CRITICAL_SECTION_ENABLED { | |
| return; | |
| } | |
| // SAFETY: The caller guarantees `cpu == curr_cpu_num()`, which is `< SMP_MAX_CPUS`. | |
| let state = unsafe { LockupDetectorState::get_unchecked(cpu) }; | |
| let outermost = enter(state); | |
| if outermost { | |
| let cs_state = &state.critical_section; | |
| // We're using Ordering::Relaxed instead of Ordering::Release to | |
| // minimize performance impact. As a result, HeartbeatLockupChecker and | |
| // CriticalSectionLockupChecker may see stale name values because there is | |
| // nothing for them to synchronize-with. | |
| cs_state.name.store(name.as_ptr(), Ordering::Relaxed); | |
| } | |
| } | |
| /// Used to indicate the CPU has left a critical section. | |
| /// | |
| /// # Safety | |
| /// | |
| /// Preemption or interrupts must be disabled on the calling CPU, and the call must balance an | |
| /// earlier call to [`lockup_begin`] on the same CPU. | |
| #[inline] | |
| pub unsafe fn lockup_end() { | |
| if !LOCKUP_CRITICAL_SECTION_ENABLED { | |
| return; | |
| } | |
| // SAFETY: `curr_cpu_num()` is always `< SMP_MAX_CPUS`. | |
| let state = unsafe { LockupDetectorState::get_unchecked(curr_cpu_num()) }; | |
| call_if_outer_and_leave(state, |state| { | |
| let cs_state = &state.critical_section; | |
| // See comment in `lockup_begin_raw_on_cpu` at the point where `name` is stored. | |
| cs_state.name.store(ptr::null_mut(), Ordering::Relaxed); | |
| }); | |
| } |