| typedef struct { |
| uint32_t type; |
| #define POWER_TYPE_AC 0 |
| #define POWER_TYPE_BATTERY 1 |
| |
| uint32_t state; |
| // state is a bitmask |
| #define POWER_STATE_ONLINE (1 << 0) |
| // online means the power source is online for POWER_TYPE_AC and the battery |
| // is present for POWER_TYPE_BATTERY |
| |
| // below 3 states are only valid for POWER_TYPE_BATTERY |
| // a battery may be discharging, charging, or neither discharging nor charging. |
| // it is illegal for both POWER_STATE_DISCHARGING and POWER_STATE_CHARGING |
| // to be set. POWER_STATE_CRITICAL is set when the battery reaches an |
| // OEM-defined critical level and the system should perform a shutdown. |
| #define POWER_STATE_DISCHARGING (1 << 1) |
| #define POWER_STATE_CHARGING (1 << 2) |
| #define POWER_STATE_CRITICAL (1 << 3) |
| } power_info_t; |
| |
| // The remaining battery percentage is calculated using the following formula: |
| // remaining battery percentage [%] = remaining_capacity / last_full_capacity * 100 |
| // |
| // The remaining battery life is calculated using the following formula: |
| // remaining_battery_life [h] = remaining_capacity / present_rate |
| |
| typedef struct { |
| uint32_t unit; |
| // capacity unit. all voltage fields are in millivolts |
| #define BATTERY_UNIT_MW 0 |
| #define BATTERY_UNIT_MA 1 |
| |
| uint32_t design_capacity; |
| // nominal capacity of a new battery |
| uint32_t last_full_capacity; |
| // predicted battery capacity when fully charged |
| uint32_t design_voltage; |
| // nominal voltage of a new battery |
| uint32_t capacity_warning; |
| // capacity when the device will generate a warning notification |
| uint32_t capacity_low; |
| // capacity when the device will generate a low battery notification |
| uint32_t capacity_granularity_low_warning; |
| // the smallest increment the battery is capable of measuring between the |
| // low and warning capacities |
| uint32_t capacity_granularity_warning_full; |
| // the smallest increment the battery is capable of measuring between the low |
| // and warning capacities |
| |
| // below fields are in units specified in battery_info_t |
| int32_t present_rate; |
| // charging/discharging rate in the capacity unit. positive is charging, |
| // negative is discharging |
| uint32_t remaining_capacity; |
| uint32_t present_voltage; |
| } battery_info_t; |
| |
| void poweroff(void); |
| void reboot(void); |
| zx_status_t suspend_to_ram(void); |
| |
| #endif // ZIRCON_SYSTEM_DEV_BUS_ACPI_INCLUDE_POWER_H_ |