| * Copyright (c) 2013-2014 Nest Labs, Inc. |
| * Copyright (c) 2019 Google, LLC. |
| * All rights reserved. |
| * |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| * |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| * |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| |
| /** |
| * @file |
| * This file defines Weave-specific constants used by the |
| * Nest Thermostat. |
| */ |
| |
| #ifndef WEAVE_PROFILES_NEST_THERMOSTAT_CONSTANTS |
| #define WEAVE_PROFILES_NEST_THERMOSTAT_CONSTANTS |
| |
| namespace nl { |
| |
| namespace Weave { |
| |
| namespace Profiles { |
| |
| namespace Vendor { |
| |
| namespace Nestlabs { |
| |
| namespace Thermostat { |
| |
| /** |
| * Thermostat-specific status codes |
| */ |
| typedef enum |
| { |
| kStatus_InFieldJoining_Unknown = -1, /**< Unknown */ |
| kStatus_InFieldJoining_Null = 0, /**< In-field joining started by the service */ |
| kStatus_InFieldJoining_Succeeded = 1, /**< In-field joining succeeded */ |
| kStatus_InFieldJoining_CannotLocateAssistingDevice = 2, /**< Failure to locate assisting device */ |
| kStatus_InFieldJoining_CannotConnectAssistingDevice = 3, /**< Failure to connect to assisting device */ |
| kStatus_InFieldJoining_CannotAuthAssistingDevice = 4, /**< Failure to authenticate to assisting device */ |
| kStatus_InFieldJoining_ConfigExtractionError = 5, /**< Error extracting configuration from assisting device */ |
| kStatus_InFieldJoining_PANFormError = 6, /**< Failure to form 802.15.4 PAN */ |
| kStatus_InFieldJoining_PANJoinError = 7, /**< Failure to join 802.15.4 PAN */ |
| kStatus_InFieldJoining_HVACCycleInProgress = 8, /**< HVAC cycle in progress */ |
| kStatus_InFieldJoining_HeatLinkJoinInProgress = 9, /**< HeatLink join in progress */ |
| kStatus_InFieldJoining_HeatLinkUpdateInProgress = 10, /**< HeatLink software update in progress */ |
| kStatus_InFieldJoining_HeatLinkManualHeatActive = 11, /**< Heatlink manual heat active */ |
| kStatus_InFieldJoining_IncorrectHeatLinkSoftwareVersion = 12, /**< Incorrect HeatLink software version */ |
| kStatus_InFieldJoining_FailureToFetchAccessToken = 13, /**< Failure to fetch access token */ |
| kStatus_InFieldJoining_DeviceNotWeaveProvisioned = 14, /**< Device not Weave provisioned */ |
| kStatus_InFieldJoining_HeatLinkResetFailed = 15, /**< Failed to factory reset HeatLink */ |
| kStatus_InFieldJoining_DestroyFabricFailed = 16, /**< Failed to destroy existing fabric */ |
| kStatus_InFieldJoining_CannotJoinExistingFabric = 17, /**< Failed to join existing fabric */ |
| kStatus_InFieldJoining_CannotCreateFabric = 18, /**< Failed to create new fabric */ |
| kStatus_InFieldJoining_NetworkReset = 19, /**< Network was reset on the device */ |
| kStatus_InFieldJoining_JoiningInProgress = 20, /**< Device already in-field joining */ |
| kStatus_InFieldJoining_FailureToMakePanJoinable = 21, /**< Assisting device failed to make its PAN joinable */ |
| kStatus_InFieldJoining_WeaveConnectionTimeoutStillActive = 22, /**< Timeout used to keep us awake while connected to another device still active */ |
| kStatus_InFieldJoining_HeatLinkNotJoined = 23, /**< HeatLink not joined to head unit */ |
| kStatus_InFieldJoining_HeatLinkNotInContact = 24, /**< HeatLink not in contact with head unit */ |
| kStatus_InFieldJoining_WiFiTechNotEnabled = 25, /**< WiFi technology is not enabled */ |
| kStatus_InFieldJoining_15_4_TechNotEnabled = 26, /**< 15.4 technology is not enabled */ |
| kStatus_InFieldJoining_StandaloneFabricCreationInProgress = 27, /**< Standalone fabric creation is in progress */ |
| kStatus_InFieldJoining_NotConnectedToPower = 28, /**< Backplate not connected to any power */ |
| kStatus_InFieldJoining_OperationNotPermitted = 29, /**< In-field joining not permitted */ |
| kStatus_InFieldJoining_ServiceTimedOut = 100, /**< Joining operation timed out (set by service) */ |
| kStatus_InFieldJoining_DeviceTimedOut = 101, /**< Joining operation timed out (set by device) */ |
| kStatus_InFieldJoining_InternalError = 200, /**< Internal error during in-field joining */ |
| |
| kStatus_InFieldJoining_MinComplete = kStatus_InFieldJoining_Succeeded, |
| kStatus_InFieldJoining_MaxComplete = kStatus_InFieldJoining_InternalError, |
| } InFieldJoiningStatus; |
| |
| #define IFJ_STATUS_COMPLETE(_result) (((_result) >= kStatus_InFieldJoining_MinComplete) && ((_result) <= kStatus_InFieldJoining_MaxComplete)) |
| |
| const char *IfjStatusStr(InFieldJoiningStatus status); |
| |
| // Thermostat-specific tags |
| // |
| // Tag Tag Element |
| // Number Category Type Constraints Disposition Readability Writability |
| // ----------------------------------------------------------------------------------------------- |
| |
| enum { |
| kTag_LegacyEntryKey = 0x0001, // Profile-specific UTF-8 String None Optional Any - |
| kTag_SystemTestStatusKey = 0x0002, // Profile-specific Unsigned Int See tbl 4 Optional Any - |
| }; |
| |
| /** |
| * Thermostat-specific status codes |
| */ |
| enum { |
| kStatus_ServiceUnreachable = 0x0001, /**< Cannot contact the Service to retrieve the Legacy Entry Key */ |
| kStatus_DeviceAlreadyPaired = 0x0002, /**< The device is already paired to a Nest account */ |
| kStatus_BatteriesNeeded = 0x0003, |
| kStatus_HvacActive = 0x0004, |
| kStatus_WiFiBlackout = 0x0005, |
| }; |
| |
| /** |
| * Thermostat-specific system test codes. Do not change these values even if a test gets deprecated. |
| * They are used in kTag_SystemTestStartKey Update requests and kTag_SystemTestStatusKey view responses. |
| */ |
| typedef enum { |
| kSystemTestCode_None = 0x00, |
| kSystemTestCode_Cooling = 0x01, |
| kSystemTestCode_Heating = 0x02, |
| kSystemTestCode_AlternateHeating = 0x03, |
| kSystemTestCode_AuxiliaryHeating = 0x04, |
| kSystemTestCode_Dehumidifier = 0x05, |
| kSystemTestCode_EmergencyHeating = 0x06, |
| kSystemTestCode_Fan = 0x07, |
| kSystemTestCode_Humidifier = 0x08, |
| kSystemTestCode_AlternateHeatStage2 = 0x09, |
| kSystemTestCode_CoolingStage2 = 0x0A, |
| kSystemTestCode_HeatingStage2 = 0x0B, |
| kSystemTestCode_HeatingStage3 = 0x0C, |
| } SystemTestCode; |
| |
| |
| /** |
| * Thermostat-specific system test status codes. Do not change these values even if a test status gets deprecated. |
| * They are used in kTag_SystemTestStatusKey view responses. The lower byte of these values will be used to store |
| * specific test codes from the SystemTestCode enum. |
| */ |
| typedef enum { |
| kSystemTestStatusCode_Idle = 0x0000, |
| kSystemTestStatusCode_Running = 0x0100, |
| kSystemTestStatusCode_Timeout = 0x0200, |
| kSystemTestStatusCode_TooHot = 0x0300, |
| kSystemTestStatusCode_TooCold = 0x0400, |
| kSystemTestStatusCode_CompressorLockout = 0x0500, |
| kSystemTestStatusCode_Invalid = 0x0600, |
| kSystemTestStatusCode_WeatherRequired = 0x0700, |
| } SystemTestStatusCode; |
| |
| /** |
| * Thermostat-specific system status codes. Do not change these values even if a status gets deprecated. |
| * They are used in kTag_SystemStatusKey view responses. |
| */ |
| typedef enum { |
| kSystemStatusCode_Idle = 0x0000, //No error codes or special conditions |
| kSystemStatusCode_NoWeatherInfo = 0x0001, //No weather info, system tests not possible |
| kSystemStatusCode_MandatoryUpdateUnknown = 0x0002, //Still checking if a mandatory update is needed |
| kSystemStatusCode_MandatoryUpdateInProgress = 0x0004, //Mandatory update in progress |
| } SystemStatusCode; |
| |
| } // namespace Thermostat |
| |
| } // namespace Nestlabs |
| |
| } // namespace Vendor |
| |
| } // namespace Profiles |
| |
| } // namespace Weave |
| |
| } // namespace nl |
| |
| #endif // WEAVE_PROFILES_NEST_THERMOSTAT_CONSTANTS |