blob: 7aecb1fb9e3803546c8055d2dc65aeaf29ddfe99 [file] [log] [blame]
/*
* Chromium OS EC driver - LPC interface
*
* Copyright 2012 Google Inc.
* See file CREDITS for list of people who contributed to this
* project.
*
* This program is free software; you can redistribute it and/or
* modify it under the terms of the GNU General Public License as
* published by the Free Software Foundation; either version 2 of
* the License, or (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program; if not, write to the Free Software
* Foundation, Inc., 59 Temple Place, Suite 330, Boston,
* MA 02111-1307 USA
*/
#include <libpayload.h>
#include "base/container_of.h"
#include "drivers/ec/cros/lpc.h"
/* Timeout waiting for a flash erase command to complete */
static const int CROS_EC_CMD_TIMEOUT_MS = 5000;
static int wait_for_sync(void)
{
uint64_t start = timer_us(0);
while (inb(EC_LPC_ADDR_HOST_CMD) & EC_LPC_STATUS_BUSY_MASK) {
if (timer_us(start) > CROS_EC_CMD_TIMEOUT_MS * 1000) {
printf("%s: Timeout waiting for CrosEC sync\n",
__func__);
return -1;
}
}
return 0;
}
static void outb_range(const uint8_t *data, uint16_t port, int size)
{
while (size--)
outb(*data++, port++);
}
static void inb_range(uint8_t *data, uint16_t port, int size)
{
while (size--)
*data++ = inb(port++);
}
static uint8_t inb_range_checksum(uint8_t *data, uint16_t port, int size)
{
uint8_t checksum = 0;
while (size--)
checksum += inb(port++);
return checksum;
}
static int send_command(CrosEcBusOps *me, uint8_t cmd, int cmd_version,
const void *dout, uint32_t dout_len,
void *din, uint32_t din_len)
{
struct ec_lpc_host_args args;
if (dout_len > EC_PROTO2_MAX_PARAM_SIZE) {
printf("%s: Cannot send %d bytes\n", __func__, dout_len);
return -1;
}
/* Fill in args */
args.flags = EC_HOST_ARGS_FLAG_FROM_HOST;
args.command_version = cmd_version;
args.data_size = dout_len;
/* Calculate checksum */
args.checksum = cmd + args.flags + args.command_version +
args.data_size + cros_ec_calc_checksum(dout, dout_len);
if (wait_for_sync()) {
printf("%s: Timeout waiting ready\n", __func__);
return -1;
}
/* Write args */
outb_range((uint8_t *)&args, EC_LPC_ADDR_HOST_ARGS, sizeof(args));
/* Write data, if any */
outb_range(dout, EC_LPC_ADDR_HOST_PARAM, dout_len);
outb(cmd, EC_LPC_ADDR_HOST_CMD);
if (wait_for_sync()) {
printf("%s: Timeout waiting for response\n", __func__);
return -1;
}
/* Check result */
int res = inb(EC_LPC_ADDR_HOST_DATA);
if (res) {
printf("%s: CrosEC result code %d\n", __func__, res);
return -res;
}
/* Read back args */
inb_range((uint8_t *)&args, EC_LPC_ADDR_HOST_ARGS, sizeof(args));
/*
* If EC didn't modify args flags, then somehow we sent a new-style
* command to an old EC, which means it would have read its params
* from the wrong place.
*/
if (!(args.flags & EC_HOST_ARGS_FLAG_TO_HOST)) {
printf("%s: CrosEC protocol mismatch\n", __func__);
return -EC_RES_INVALID_RESPONSE;
}
if (args.data_size > din_len) {
printf("%s: CrosEC returned too much data %d > %d\n",
__func__, args.data_size, din_len);
return -EC_RES_INVALID_RESPONSE;
}
uint8_t csum = 0;
if (din) {
/* Read data, if any */
inb_range(din, EC_LPC_ADDR_HOST_PARAM, args.data_size);
csum = cros_ec_calc_checksum(din, args.data_size);
} else {
csum = inb_range_checksum(din, EC_LPC_ADDR_HOST_PARAM,
args.data_size);
}
/* Verify checksum */
csum += cmd + args.flags + args.command_version + args.data_size;
if (args.checksum != csum) {
printf("%s: CrosEC response has invalid checksum\n", __func__);
return -EC_RES_INVALID_CHECKSUM;
}
/* Return actual amount of data received */
return args.data_size;
}
/**
* Initialize LPC protocol.
*
* @param dev CrosEC device
* @param blob Device tree blob
* @return 0 if ok, -1 on error
*/
static int cros_ec_lpc_init(CrosEcBusOps *me)
{
int byte, i;
/* See if we can find an EC at the other end */
byte = 0xff;
byte &= inb(EC_LPC_ADDR_HOST_CMD);
byte &= inb(EC_LPC_ADDR_HOST_DATA);
for (i = 0; i < EC_PROTO2_MAX_PARAM_SIZE && (byte == 0xff); i++)
byte &= inb(EC_LPC_ADDR_HOST_PARAM + i);
if (byte == 0xff) {
printf("%s: CrosEC device not found on LPC bus\n",
__func__);
return -1;
}
return 0;
}
CrosEcLpcBus *new_cros_ec_lpc_bus(void)
{
CrosEcLpcBus *bus = xzalloc(sizeof(*bus));
bus->ops.init = &cros_ec_lpc_init;
bus->ops.send_command = &send_command;
return bus;
}