| # i2cutil | |
| List, read from, and write to I2C devices. | |
| ## Usage | |
| ```none | |
| i2cutil read <device> <address> [<address>...] | |
| i2cutil write <device> <address> [<address>...] <data> [<data>...] | |
| i2cutil transact <device> (r <bytes>|w <address> [<address>...] [<data>...])... | |
| i2cutil dump <device> <address> <count> | |
| i2cutil list | |
| i2cutil ping | |
| i2cutil help | |
| ``` | |
| ## Commands | |
| ### read {#read} | |
| ```none | |
| i2cutil read <device> <address> [<address>...] | |
| ``` | |
| Read one byte from an I2C device. Use [`transact`](#transact) | |
| to read multiple bytes. `<device>` can be the full path of | |
| a devfs node (example: `/dev/class/i2c/031`) or only the | |
| devfs node's index (example: `31`) or it can simply be the | |
| device's friendly named obtained via `i2cutil list`. Use | |
| [`ping`](#ping) to get devfs node paths and indexes. | |
| `<address>` is the internal register of `<device>` to read | |
| from. Use multiple `<address>` values to access a multi-byte | |
| (little-endian) register address. For example | |
| `i2cutil read 4 0x20 0x3D` to read the register at `0x203D`. | |
| ### write {#write} | |
| ```none | |
| i2cutil write <device> <address> [<address>...] <data> [<data>...] | |
| ``` | |
| Write one or more bytes (`<data>`) to an I2C device. See the | |
| [`read`](#read) description for explanations of `<device>` | |
| and `<address>`. | |
| ### transact {#transact} | |
| ```none | |
| i2cutil transact <device> (r <bytes>|w <address> [<address>...] [<data>...])... | |
| ``` | |
| Perform a transaction with multiple segments. Each segment can be a write | |
| (`w`) or a read (`r`). | |
| ### dump {#dump} | |
| ```none | |
| i2cutil dump <device> <start> <count> | |
| ``` | |
| Reads and prints `<count>` registers from `<device>` starting at the address | |
| indicated by `<address>` | |
| ### list {#list} | |
| ```none | |
| i2cutil list | |
| ``` | |
| Lists all I2C devices available on the system. The friendly name of the device will | |
| also be listed if one is provided. Otherwise the device will appear as `(ANONYMOUS)`. | |
| ### ping {#ping} | |
| ```none | |
| i2cutil ping | |
| ``` | |
| Ping all I2C devices under devfs path `/dev/class/i2c` by | |
| reading from each device's `0x00` address. | |
| ### help {#help} | |
| ```none | |
| i2cutil help | |
| ``` | |
| Print help text. | |
| ## Examples | |
| ### Read one byte | |
| Read one byte from the register at `0x20` of the I2C device | |
| represented by devfs node index `4`: | |
| ```none | |
| $ i2cutil read 4 0x20 | |
| ``` | |
| ### Read three bytes | |
| Read three bytes from the register at `0x20` of the I2C device | |
| represented by devfs node index `4`: | |
| ```none | |
| $ i2cutil transact 4 w 0x20 r 3 | |
| ``` | |
| ### Dump nine registers starting at address 0x10 | |
| Dump nine registers starting at address 0x10. | |
| ```none | |
| $ i2cutil dump pmic 0x10 9 | |
| 0x10: 0x00 | |
| 0x11: 0x00 | |
| 0x12: 0x00 | |
| 0x13: 0x00 | |
| 0x14: 0x00 | |
| 0x15: 0x00 | |
| 0x16: 0x00 | |
| 0x17: 0x00 | |
| 0x18: 0x00 | |
| ``` | |
| ### Read one byte from a multi-byte address | |
| Read one byte from the register at the multi-byte address `0x203D` | |
| of the I2C device represented by devfs node index `4`: | |
| ```none | |
| $ i2cutil read 4 0x20 0x3D | |
| ``` | |
| ### Read one byte using a devfs node path | |
| Read one byte from the register at the multi-byte address `0x203D` | |
| of the I2C device represented by the devfs node path | |
| `/dev/class/i2c/004`: | |
| ```none | |
| $ i2cutil read /dev/class/i2c/004 0x20 0x3D | |
| ``` | |
| ### Read one byte using the device's friendly name | |
| Read one byte from the register at the multi-byte address `0x203D` | |
| of the I2C device named `temp_sensor`: | |
| ```none | |
| $ i2cutil list | |
| 378: temp_sensor | |
| 379: (ANONYMOUS) | |
| 380: humidity_sensor | |
| 381: pmic | |
| $ i2cutil read temp_sensor 0x20 0x3D | |
| ``` | |
| ### Write one byte | |
| Write one byte `0x12` to the register at `0x2C` of the I2C device represented by | |
| devfs node index `3`: | |
| ```none | |
| $ i2cutil write 3 0x2C 0x12 | |
| ``` | |
| ### Write two bytes using a devfs node path | |
| Write two bytes `0x121B` to the register at `0x2C` of the | |
| I2C device represented by devfs node index `/dev/class/i2c/003`: | |
| ```none | |
| $ i2cutil write /dev/class/i2c/003 0x2C 0x12 0x1B | |
| ``` | |
| Caution: This exact same command could mean "write byte `0x1B` | |
| to register `0x2C12` for a different I2C device. The meaning | |
| of the arguments depends on the I2C device. | |
| ### Ping all I2C devices | |
| Read the `0x00` address of all devices found under | |
| `/dev/class/i2c`. | |
| ```none | |
| $ i2cutil ping | |
| /dev/class/i2c/821: OK | |
| /dev/class/i2c/822: OK | |
| /dev/class/i2c/823: OK | |
| /dev/class/i2c/824: OK | |
| Error ZX_ERR_TIMED_OUT | |
| /dev/class/i2c/825: ERROR | |
| ``` | |
| ### List all I2C devices | |
| List all I2C devices on the system along with their friendly names if one is available. | |
| ```none | |
| $ i2cutil list | |
| 378: temp_sensor | |
| 379: (ANONYMOUS) | |
| 380: humidity_sensor | |
| 381: pmic | |
| ``` | |
| ## Notes | |
| ### Source code | |
| Source code for `i2cutil`: [`//src/devices/i2c/bin/i2cutil.cc`](/src/devices/i2c/bin/i2cutil.cc) | |
| <!-- | |
| // LINT.ThenChange(//src/devices/i2c/bin/i2cutil.cc) | |
| --> |