src/power/power-manager/thermal_config/README.md

Central thermal trip point configuration

This directory contains the central thermal trip point parser library and validator program.

Context

The purpose of the central thermal trip point configuration is to create a file where the trip point configuration for all clients in the system can be defined in a single place. Having all trip points in a single location aims to provide a few benefits:

  1. Improved maintainability.
  2. Easier reasoning about a system’s holistic thermal throttling scheme.
  3. Better alignment with the general direction of central configuration owned by the Power Manager, similar to the low-power mode configuration system.
  4. Improved ability to support per-sensor trip point configurations, which will be needed to support more advanced throttling policies, and isn’t achievable with the current thermal interface

Example configuration

{
    clients: {
        audio: [
            {
                state: 1,
                trip_points: [
                    {
                        sensor: '/dev/sys/platform/05:03:a/thermal',
                        activate_at: 75,
                        deactivate_below: 71,
                    },
                ],
            },
            {
                state: 2,
                trip_points: [
                    {
                        sensor: '/dev/sys/platform/05:03:a/thermal',
                        activate_at: 86,
                        deactivate_below: 82,
                    },
                ],
            },
        ],
    },
}

Format

The configuration begins with a top-level key, clients, which contains an entry for each configured thermal client. The key name for each client entry must match the client_type identifier that a client will specify in the call to fuchsia.thermal.ClientStateConnector/Connect.

The value for each client entry is an array of the client’s supported thermal states. A thermal state is described by two keys:

  • state - the thermal state value (unsigned integer) that this object describes
  • trip_points - an array of trip points that will activate this thermal state

A “trip point” is described by three keys:

  • sensor - path to the sensor driver that this trip point corresponds to
  • activate_at - the thermal load at which this trip point will become active
  • deactivate_below - the thermal load at which this trip point becomes deactivated

Adding board support

To add support for a new board:

  1. Create a new board-specific JSON5 file, taking care to follow the correct format (detailed below)
  2. In your new JSON5 file, add a client entry and associated trip points for each thermal client you wish to support
  3. Define a thermal_config build target for the new JSON5 file and include it in the respective board-specific gni file

Validation

The thermal_config GN template implements a built-in validator. The validator runs at compile time as long as the thermal_config target is included in the build graph. It will ensure 1) the file is valid JSON5, and 2) the JSON5 format adheres to the expected format (defined by the parsing library here).

Raw temperature vs thermal load

Trip points are described in terms of “thermal load” instead of raw temperatures. Therefore, if trip points based on raw temperatures are desired, those raw temperatures must first be converted into equivalent thermal load values.

Background on thermal load – “thermal load” is simply an integer in the range [0..100] which represents the severity of thermals at a given sensor. A thermal load value of 0 corresponds to “thermally unthrottled” while a value of 100 corresponds to “max thermal throttling” and typically results in a system shutdown. Thermal load is calculated as an interpolation between a “start” and “end” temperature (corresponding to “throttling onset” and “emergency reboot” temperatures, respectively).

To convert the desired raw temperature trip points into corresponding thermal load trip points, we must first choose “onset” and “reboot” threshold temperatures for each sensor, which will be configured internally in the Power Manager’s node configuration (example: Nelson). Once the “onset” and “reboot” temperature thresholds are determined, we can apply the following formula to convert the desired raw temperature for each trip point into the equivalent thermal load value:

thermal_load = (T - T_onset) / (T_reboot - T_onset) * 100

Trip point configuration

The specific trip point configuration for each client does not follow any one-size-fits-all approach. Typically, it is the responsibility of the system integrator interested in thermal management to determine the appropriate thermal trip points for each client. The configuration should consider:

  • how many thermal throttle states are supported by a given client
  • when should throttling be applied for a client relative to other clients
  • when should throttling be applied for a client relative to emergency thermal reboot

Theory of operation

Client usage

A supported client may use the fuchsia.thermal.ClientStateConnector/Connect method to connect a fuchsia.thermal.ClientStateWatcher channel to the Power Manager, which can then be used to query its current thermal state. The state returned by this method will be an integer corresponding to a specific trip point from that client's entry in the configuration file. It is up to the client to implement actions resulting from thermal state changes.

Power Manager usage

The configuration files are intended to be consumed directly by the Power Manager component. When the Power Manager starts up, it will read in the configuration file from the filesystem. When a client requests its current thermal state, the Power Manager will use available system temperature information in combination with that client's trip point configuration to determine the appropriate thermal state.

Thermal state selection

The Power Manager is responsible for continuously monitoring temperature levels at each sensor. As temperature increases into the range of a client’s configured trip points, the Power Manager must determine the appropriate thermal state for the client, and communicate it to the client.

To select a client’s thermal state, the Power Manager will iterate over the client’s states and associated trip points. If any of the state’s trip points are matched, then that thermal state is chosen and the iteration will stop.